Standard Electrical Ratings are:
Electrical Rating Code
Input Power
A 90 - 130 VAC 50/60 Hz
E 180 - 260 VAC 50/60 Hz
D 18 - 30 VDC
The Switch Types are:
Switch Code
Switch Type Switch Rating
Leakage Current
A Solid State
SPDT
12-140 VAC
3 Amp Resistive
5 mA max
D Solid State
SPDT
5-60 VDC
3 Amp Resistive
1 mA max
R Relay SPDT 115 VAC
24 VDC
3 Amp Resistive
N/A
OPTIONS
The 801P5 options are listed below. You can combine these
options, but every option ordered should be indicated in the part
number of the unit.
Option Description
E 7/16"-20 SAE Pressure Port
Q Scalable Readout
V Analog Output, 4 - 20 mA